Description
Protector Echo Filtered Floor-Mounted Fume Hoods provide the interior height needed for bulky apparatus with no ducting required. These hoods feature fully-closing, vertical-rising sashes. eGuard® communication software offers real-time monitoring on the users phone or computer. From a remote location, data such as usage authorization, filter saturation detection, sash position & temperature may be observed & managed.
The Echo uses Neutrodine® Unisorb Filters, the most comprehensive, safety-driven carbon filter available. This single molecular filter type can easily adsorb most chemicals & mixtures, taking the guesswork out of filter selection. Erlab-proven Neutrodine Filters are the heart of GFH Filtration Technology.
Floor-Mounted models include a fiberglass panelized liner & three exterior depths: 37.7 in., 43.7 in., and 55.7 in. Models are available for carbon-only, carbon with acid sensor, carbon with formaldehyde sensor, or HEPA-only filtration. Filters are sold separately.
Features
• Eco-Foil™ air foil with aerodynamic Clean-Sweep™ airflow openings
• Cord-Keeper™ Slots on left and right side of air foil
• Single piece, tempered safety glass vertical-rising sashes with cable pulley, sash weight and powder-coated aluminum sash handle and tracks with Clean-Sweep™ airflow openings.
• Removable front & side panels, and front & interior service access panels for access to plumbing and electrical wiring
• eGuard2 software communication
• Smart control module with wifi, Bluetooth and ethernet connectivity
• Factory-installed command module, fan button and light button
• Rear baffle
• By-pass airflow design
• Glacier white powder-coated steel exterior
• Chemical-resistant, fiberglass-reinforced, composite panel liner
• Pre-wired vapor-proof LED lights for up to 63 foot candles rated for 50,000 hours
• Factory-prepared for up to two electrical duplex receptacles and six service fixtures
• Roughing prefilters
• Built-in exhaust fans to maintain 60 fpm face velocity with only an upper sash opening height of 16 in.
• Sound pressure of <60 dB(A) with sash at operating height and <48 dB(A) with sash closed
• Sensor package for primary filter breakthrough of solvent and acid fumes, laboratory air quality, sash position, and temperature
• Audible/visual alarms for breakthrough detection, temperature 40°C (104°F), fan failure & high sash position opening. At 60°C (140°F), all fans stop
• Power cord with plug
• Two pre-plumbed service fixtures for gas and water. Components for converting either or both fixtures to air & vacuum are provided. Inlet tubing is not included.
• One pre-wired GFCI electrical duplex receptacle (two on 8 ft. models only)
Required Accessories (Not Included)
• Neutrodine® Unisorb Filters (except HEPA only models which require HEPA filters). Number of filters required is determined by the width of the hood
Available Options
• HEPA filter
• Region-specific electrical plug configurations
• Service fixtures
Specifications
• Airflow Type: Bypass
• Product Subcategory: General Chemistry
• Air foil Type: Eco-Foil
• Blower Requirements: Integral blower included
• Conformance: AFNOR NF-X, ANSI Z9.5, ASTM E84, CAN/CSA C22.2, Modified ASHRAE 110, SEFA 9, UL 61010
• Enclosure Height: 102.2 in.
• Lighting: LED
• Sash Type: Cable and pulley
• Service Fixtures: 2
• Style: Floor-Mounted
Image(s) are representative of the product group and not necessarily the individual product.