Mounting Medium With DAPI – Aqueous, Fluoroshield

Login to See Prices

Applications : ISH, IHC-P, IHC-Fr, ICC/IF
Form : Liquid
Weight 5 lbs
Dimensions 10 × 10 × 10 in
Brand

Size/Quantity

Product Size

Shipping Condition

Manufacturer Part No

SKU: ab104139 Category:

Description

Fluoroshield with DAPI is an aqueous mounting medium for preserving fluorescence of tissue and cell smears. This unique formula prevents rapid photobleaching of FITC, Texas Red, AMCA, Cy2, Cy3, Cy5, Alexa fluoro 488, Alexa fluoro 594, Green fluorescent protein (GFP), tetramethyly rhodamine, Redox. Phycoerythrin (RP-E), Phyocyanin (PC), and Allophycocyanin (APC). Fluorescence is retained during prolonged storage at 4oC in the dark. This medium does not contain phenylenediamine, which destroys immunofluorescence of Cy dyes, RP-E, PC and APC.

This mounting medium is fortified with DAPI which is a counter-stain for DNA. This product is to be used in situ hybridization techniques or other methods where fluorescence of DNA staining is required. DAPI excites at 360nm and emits at 460nm, producing a blue fluorescence. RNA is also stained with DAPI.

Procedure

  1. Bring the vial to room temperature.
  2. Rinse slide to be mounted with distilled or deionized, touch the edges of slide on a paper towel to remove excess water. Place slides on a flat surface.
  3. Turn the vial upside down and open the dropper to remove any air bubbles.
  4. Apply 3-4 drops of mounting medium directly on top of the specimen and spread out evenly by tilting slide back and forth or spread evenly with a 0.2 ml plastic pipette tip making sure the tissue is not touched. Excess medium can be removed by touching the edges of slide against paper towel.
  5. Let stand at room temperature for about 5 minutes.
  6. Apply cover slip carefully avoiding air bubbles.
  7. The specimen is ready for visualization under a microscope.
  8. One can seal the edges of cover slip with nail polish, any organic medium or our Organo mounting medium (ab104141). If a coverslip is not sealed air bubbles will appear in few days.
  9. For storage it is recommended that the slide be stored in the dark at 2-8°C.

Removal of Coverslip

Coverslip can be removed before sealing the edges. Soak slide in warm (37°C) distilled or deiononized water for several minutes. Carefully and slowly move the coverslip. Soak in water for an additional few minutes to remove coverslip. Rinse slide several times with warm water to remove all mounting medium. The slide can be remounted again.

Mounting Medium with DAPI ab104139 (previously called Fluoroshield Mounting Medium With DAPI) is an aqueous anti-fade mounting medium designed to preserve fluorescence when imaging tissues and cell samples. It is fortified with DAPI as a counter-stain for DNA (DAPI also stains RNA).

The formulation prevents rapid photobleaching of FITC, Texas Red, AMCA, Cy2, Cy3, Cy5, Alexa fluoro 488, Alexa fluoro 594, Green fluorescent protein (GFP), tetramethyly rhodamine, R-Phycoerythrin (R-PE), Phyocyanin (PC), and Allophycocyanin (APC).

Fluorescence is retained during prolonged storage at 4°C in the dark. This medium does not contain phenylenediamine, which destroys immunofluorescence of Cy dyes, R-PE, PC and APC.

Mounting media products

For fluorescent cell and tissue staining, Abcam recommends aqueous, anti-fade Fluorescence Mounting Medium ab104135, Mounting Medium with PI ab104129, and this product, Mounting Medium with DAPI ab104139. For thick sections or tissues containing lots of fat, we recommend Glycerol Mounting Medium with DAPI ab188804.

For chromogenic immunohistochemistry, such as with DAB, AEC, or Fast Red, we recommend aqueous Mounting Medium ab64230, or organic Limonene Mounting Medium ab104141.

Procedure

– Bring the vial to room temperature.

– Rinse slide to be mounted with distilled or deionized water, touch the edges of slide on a paper towel to remove excess water. Place slides on a flat surface.

– Turn the vial upside down and open the dropper to remove any air bubbles.

– Apply 3-4 drops of mounting medium directly on top of the specimen and spread out evenly by tilting slide back and forth or spread evenly with a 0.2 ml plastic pipette tip making sure the tissue is not touched. Excess medium can be removed by touching the edges of slide against paper towel.

– Let stand at room temperature for about 5 minutes.

– Apply cover slip carefully avoiding air bubbles.

– The specimen is ready for visualization under a microscope.

Seal the edges of cover slip with nail polish, any organic medium or Limonene mounting medium ab104141. If a coverslip is not sealed, air bubbles will appear in a few days.

Store the slide in the dark at 2-8°C.

Removal of Coverslip
Coverslip can be removed before sealing the edges. Soak slide in warm (37°C) distilled or deiononized water for several minutes. Carefully and slowly move the coverslip. Soak in water for an additional few minutes to remove coverslip. Rinse slide several times with warm water to remove all mounting medium. The slide can be remounted again.

Please Submit Your Inquiries Below
Name(Required)
This field is for validation purposes and should be left unchanged.
What Makes Us Unique?

The Adva Tech portfolio offers a comprehensive workflow for your manufacturing needs with wide range of services that includes on site Inventory Management, Procurement Management, and Manufacturing Capabilities such as custom pack and private labeling.

Every client in the life science reagents and chemicals industry has unique needs and deserve unique solutions.

By partnering with the Adva Tech team, you will be supported throughout the life cycle of your product. This collaboration results in building better products, increasing efficiencies, and reducing cost & waste.

Adva Tech team is committed to your success and ready to help your company meet and exceed expectations.

Learn More