Description
Benefits
• Large 7-inch, high-resolution color display
• Responsive capacitive touchscreen operable with gloves
• Angled display to help ensure ergonomic viewing
• Streamlined, easy to operate user interface
• Vertical meter orientation helps optimize bench space
• Supports GLP compliance
• Stores 20 calibration logs per parameter with date and time
• Stores 10,000 data log sets with date and time
• Outputs to a printer, computer, or USB flash drive for long-term data retention
• Inputs sample ID with optional USB barcode scanner, USB keyboard, or USB mouse
• Up to two meter-controlled and meter-powered stirrer probes
pH
Range: -2.000 to 20.000 pH
Resolution: 0.1, 0.01 or 0.001 pH
Relative accuracy: +/- 0.002 pH
Calibration points: 1 to 5 points
Calibration method: Automatic buffer recognition, manual entry option
Calibration buffer sets: USA (1.68, 4.01, 7.00, 10.01, 12.46); DIN (1.68, 4.01, 6.86, 9.18, 12.46); Pure Water Buffers (4.10, 6.97, 9.15); Standard (1.00, 3.00, 6.00, 8.00, 10.00, 13.00); Up to 5 custom buffers
Slope type: Linear or segmented
Ion
Range: 0.0001 to 19999
Resolution: 0.0001 minimum, 1 to 5 digits
Relative accuracy:+/- 0.2 mV or +/-0.05 % of the reading, whichever is greater
Units: ppt, ppm, ppb, mg/L, M, mM, %, none or user-defined
Calibration points: 1 to 5 points
Calibration method: Automatic standard recognition, manual entry option
Calibration standards:1.000, 10.00, 100.0, 1000; 10000 or up to 5 custom standards
Slope type: Linear or segmented
Calibration summary:Slope and Eo offset, option to view as point-to-point graph
Isopotential point:1.000, user adjustable
Blank correction: Yes
Low level stability: Yes
Incremental techniques: Single known addition, single known subtraction, double known addition, double known subtraction, analyte addition and analyte subtraction
Conductivity
Range: 0.010 S/cm to 3000 mS/cm
Resolution: 0.001 µS/cm minimum, auto-ranging, up to 4 digits
Relative accuracy: +/-0.5% reading
Calibration points: 1 to 5 points
Calibration method: Automatic standard recognition, manual entry option
Calibration standards: Orion (100.0 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.9 mS/cm) or up to 4 custom standards
Nominal cell constant: 0.100 cm-1, 0.475 cm-1, 0.550 cm-1, 1.000 cm-1, 10.00 cm-1 or user-defined from 0.001 to 199.9 cm-1
Temperature compensation: Linear (0.00 to 10.00 %/ DEG C), nLFn (non-linear ultra-pure water), nLFu (non-linear ultra-pure degassed water), EP/USP or off
Reference temperature: 5, 10, 15, 20, 25 or 30 DEG C
Image(s) are representative of the product group and not necessarily the individual product.